Dan you can remove the cap and check it with an ohm meter for a dead short or low resistance. If working properly the meter will show zero for an instant then steadily rise to an open reading. There is the possibility of this correct reading but the cap will break down when voltage is applied (by the circuit). I would be inclined to replace with a higher voltage cap as opposed to higher temp ratings.
__________________
System: ML:5206,5302 Serafino's Nordost Lumin U1 RM15