Quote:
Originally Posted by meltemi
Since you cannot calculate filters or anything else on a native SACD (DSD) signal, the DG-68 seems to downsample DSD to 352.8kHz (DXD) and then seems to calculate the filters with 352.8kHz (DXD).
I write "seems", because Accuphase does not specify this for the DG-68.
(In the DG-58, which provides only HS-Link Ver.1, DSD is downsampled to 176.4kHz.)
A 352.8kHz (DXD) signal is only available on HS-Link Ver.2
|
New here, happy to be part of this group
A question, having DP 750 and then enjoying MDSD.
Having now DG68 Downsampling the DSD to DXD is indeed a great improvement from DG58.
Would this operation to preserve the dynamic range of the DSD been edited in DXD for DSP then converted back to DSD or kept in PCM DXD for return to DP 750 ?
Basically is DSP and DG 68 are compatible with the whole purpose to have MDSD ?